Evaluation of computer-assisted mandibular reconstruction with vascularized fibular flap compared to conventional surgery.

Related Articles

Evaluation of computer-assisted mandibular reconstruction with vascularized fibular flap compared to conventional surgery.

Oral Surg Oral Med Oral Pathol Oral Radiol. 2016 Feb;121(2):139-48

Authors: Zhang L, Liu Z, Li B, Yu H, Shen SG, Wang X

Abstract
OBJECTIVE: The purpose of this study was to evaluate the accuracy of computer-assisted mandibular reconstruction with a vascularized fibular flap and compare it with conventional surgery.
STUDY DESIGN: In this retrospective study conducted between February 2009 and December 2012, 8 patients underwent computer-assisted mandibular reconstruction, and 14 patients underwent conventional surgery. The accuracy of virtual surgical planning was determined, and the outcomes in the two groups were compared.
RESULTS: In the computer-assisted group, the deviation in fibula segment length was 1.34 ± 1.09 mm, the angular deviation was 2.29 ± 1.19°, and the mean 3-D deviation was 0.53 ± 0.06 mm. Mean differences in intercondylar distance, intergonial angle distance, anteroposterior distance, gonial angle, and duration of ischemia were all improved in the computer-assisted group compared with the conventional surgery group.
CONCLUSIONS: Computer-assisted surgery, including preoperative virtual surgical planning, intraoperative cutting and reconstructive guides, and postoperative analysis is highly accurate in fibular flap mandibular reconstruction.

PMID: 26792754 [PubMed - in process]