Related Articles |
The use of a novel perfusion-based cadaveric simulation model with cerebrospinal fluid reconstitution comparing dural repair techniques: a pilot study.
Spine J. 2017 Sep;17(9):1335-1341
Authors: Bakhsheshian J, Strickland BA, Patel NN, Jakoi AM, Minneti M, Zada G, Acosta FL, Hsieh PC, Wang JC, Liu JC, Pham MH
Abstract
BACKGROUND CONTEXT: Watertight dural repair is crucial for both incidental durotomy and closure after intradural surgery.
PURPOSE: The study aimed to describe a perfusion-based cadaveric simulation model with cerebrospinal fluid (CSF) reconstitution and to compare spine dural repair techniques.
STUDY DESIGN/SETTING: The study is set in a fresh tissue dissection laboratory.
SAMPLE SIZE: The sample includes eight fresh human cadavers.
OUTCOME MEASURES: A watertight closure was achieved when pressurized saline up to 40 mm Hg did not cause further CSF leakage beyond the suture lines.
METHODS: Fresh human cadaveric specimens underwent cannulation of the intradural cervical spine for intrathecal reconstitution of the CSF system. The cervicothoracic dura was then exposed from C7-T12 via laminectomy. The entire dura was then opened in six cadavers (ALLSPINE) and closed with 6-0 Prolene (n=3) or 4-0 Nurolon (n=3), and pressurized with saline via a perfusion system to 60 mm Hg to check for leakage. In two cadavers (INCISION), six separate 2-cm incisions were made and closed with either 6-0 Prolene or 4-0 Nurolon, and then pressurized. A hydrogel sealant was then added and the closure was pressurized again to check for further leakage.
RESULTS: Spinal laminectomy with repair of intentional durotomy was successfully performed in eight cadavers. The operative microscope was used in all cases, and the model provided a realistic experience of spinal durotomy repair. For ALLSPINE cadavers (mean: 240 mm dura/cadaver repaired), the mean pressure threshold for CSF leakage was observed at 66.7 (±2.9) mm Hg in the 6-0 Prolene group and at 43.3 (±14.4) mm Hg in the 4-0 Nurolon group (p>.05). For INCISION cadavers, the mean pressure threshold for CSF leakage without hydrogel sealant was significantly higher in 6-0 Prolene group than in the 4-0 Nurolon group (6-0 Prolene: 80.0±4.5 mm Hg vs. 4-0 Nurolon: 32.5±2.7 mm Hg; p<.01). The mean pressure threshold for CSF leakage with the hydrogel sealants was not significantly different (6-0 Prolene: 100.0±0.0 mm Hg vs. 4-0 Nurolon: 70.0±33.1 mm Hg). The use of a hydrogel sealant significantly increased the pressure thresholds for possible CSF leakage in both the 6-0 Prolene group (p=.01) and the 4-0 Nurolon group (p<.01) when compared with mean pressures without the hydrogel sealant.
CONCLUSIONS: We described the feasibility of using a novel cadaveric model for both the study and training of watertight dural closure techniques. 6-0 Prolene was observed to be superior to 4-0 Nurolon for watertight dural closure without a hydrogel sealant. The use of a hydrogel sealant significantly improved watertight dural closures for both 6-0 Prolene and 4-0 Nurolon groups in the cadaveric model.
PMID: 28412565 [PubMed - indexed for MEDLINE]
from #ENT-PubMed via ola Kala on Inoreader https://ift.tt/2Hq4hHE
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου