Αρχειοθήκη ιστολογίου

Κυριακή 13 Αυγούστου 2017

Experimental validation of predicted application accuracies for computer-assisted (CAS) intraoperative navigation with paired-point registration.

Related Articles

Experimental validation of predicted application accuracies for computer-assisted (CAS) intraoperative navigation with paired-point registration.

Int J Comput Assist Radiol Surg. 2017 Aug 11;:

Authors: Perwög M, Bardosi Z, Freysinger W

Abstract
PURPOSE: The target registration error (TRE) is a crucial parameter to estimate the potential usefulness of computer-assisted navigation intraoperatively. Both image-to-patient registration on base of rigid-body registration and TRE prediction methods are available for spatially isotropic and anisotropic data. This study presents a thorough validation of data obtained in an experimental operating room setting with CT images.
METHODS: Optical tracking was used to register a plastic skull, an anatomic specimen, and a volunteer to their respective CT images. Plastic skull and anatomic specimen had implanted bone fiducials for registration; the volunteer was registered with anatomic landmarks. Fiducial localization error, fiducial registration error, and total target error (TTE) were measured; the TTE was compared to isotropic and anisotropic error prediction models. Numerical simulations of the experiment were done additionally.
RESULTS: The user localization error and the TTE were measured and calculated using predictions, both leading to results as expected for anatomic landmarks and screws used as fiducials. TRE/TTE is submillimetric for the plastic skull and the anatomic specimen. In the experimental data a medium correlation was found between TRE and target localization error (TLE). Most of the predictions of the application accuracy (TRE) fall in the 68% confidence interval of the measured TTE. For the numerically simulated data, a prediction of TTE was not possible; TRE and TTE show a negligible correlation.
CONCLUSION: Experimental application accuracy of computer-assisted navigation could be predicted satisfactorily with adequate models in an experimental setup with paired-point registration of CT images to a patient. The experimental findings suggest that it is possible to run navigation and prediction of navigation application accuracy basically defined by the spatial resolution/precision of the 3D tracker used.

PMID: 28801767 [PubMed - as supplied by publisher]



from #ENT-PubMed via ola Kala on Inoreader http://ift.tt/2vuxwVY

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου