Αρχειοθήκη ιστολογίου

Παρασκευή 29 Σεπτεμβρίου 2017

Stress distribution of single-implant–retained overdenture reinforced with a framework: A finite element analysis study

alertIcon.gif

Publication date: Available online 28 September 2017
Source:The Journal of Prosthetic Dentistry
Author(s): Camilla F. Amaral, Rafael S. Gomes, Renata C.M. Rodrigues Garcia, Altair A. Del Bel Cury
Statement of problemStudies have demonstrated the effectiveness of a single-implant–retained mandibular overdenture for elderly patients with edentulism. However, due to the high concentration of stress around the housing portion of the single implant, this prosthesis tends to fracture at the anterior region more than the 2-implant–retained mandibular overdenture.PurposeThe purpose of this finite-element analysis study was to evaluate the stress distribution in a single-implant–retained mandibular overdenture reinforced with a cobalt-chromium framework, to minimize the incidence of denture base fracture.Material and methodsTwo 3-dimensional finite element models of mandibular overdentures supported by a single implant with a stud attachment were designed in SolidWorks 2013 software. The only difference between the models was the presence or absence of a cobalt-chromium framework at the denture base between canines. Subsequently, the models were imported into the mathematical analysis software ANSYS Workbench v15.0. A mesh was generated with an element size of 0.7 mm and submitted to convergence analysis before mechanical simulation. All materials were considered to be homogeneous, isotropic, and linearly elastic. A 100-N load was applied to the incisal edge of the central mandibular incisors at a 30-degree angle. Maximum principal stress was calculated for the overdenture, von Mises stress was calculated for the attachment and implant, and minimum principal stress was calculated for cortical and cancellous bone.ResultsIn both models, peak stress on the overdenture was localized at the anterior intaglio surface region around the implant. However, the presence of the framework reduced the stress by almost 62% compared with the overdenture without a framework (8.7 MPa and 22.8 MPa, respectively). Both models exhibited similar stress values in the attachment, implant, and bone.ConclusionsA metal framework reinforcement for a single-implant–retained mandibular overdenture concentrates less stress through the anterior area of the prosthesis and could minimize the incidence of fracture.



from #ORL-AlexandrosSfakianakis via ola Kala on Inoreader http://ift.tt/2yM8MZf

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου