Speech Production Quality of Cochlear Implant Users with Respect to Duration and Onset of Hearing Loss

224270?imgType=4

Purpose: To assess whether postlingual onset and shorter duration of deafness before cochlear implant (CI) provision predict higher speech intelligibility results of CI users. Methods: For an objective judgement of speech intelligibility, we used an automatic speech recognition system computing the word recognition rate (WR) of 50 adult CI users and 50 age-matched control individuals. All subjects were recorded reading a standardized text. Subjects were divided into three groups: pre- or perilingual deafness (A), both >2 years before implantation, postlingual deafness 2 years before implantation (C). Results: CI users with short duration of postlingual deafness (B) had a significantly higher WR (median 74%) than CI users with long duration of postlingual deafness (C; 68%, p p Conclusions: The speech production quality of adult CI users shows dependencies on the onset and duration of deafness. These features need to be considered while planning rehabilitation.
ORL 2017;79:282-294